Eight-dot extended corporotomy: A more secure, aesthetic and time efficient technique for semirigid penile prosthesis implantation

  • Ragheb, A.M.
  • Ahmed M. Ragheb
  • VJPU_2019_3_154
  • 3:26
Image

Abstract

Authors

Ahmed M. Ragheb

Key Words

Eight-dot, Corporotomy, Penile implant

Description

This video introduces a new approach that may simplify semirigid penile prosthesis implantation (SPPI) while ensuring implant integrity and optimizing procedure efficiency and accuracy. Through an illustrated live surgery video, we demonstrate step by step the 8-dot extended corporotomy preplaced suture technique that avoids overbending of implant rods and potentially weakening them during implantation and leading to future spontaneous fracture as formerly postulated or by needle nicking during corporotomy suturing. Via a purely scrotal incision, a self-retaining mastoid retractor is used for maintained exposure throughout the procedure. The 8-dot corporotomy is a simple technique that facilitates all steps of SPPI in a timely and secure manner. Moreover, the purely scrotal approach using the self-retaining mastoid retractor not only allows applying the “No touch” technique for SPPI but results in a more aesthetic outcome compared to the classic penoscrotal or subcoronal incisions. The fact that self-retaining mastoid retractors are readily available may allow surgeons in underserved areas to provide good quality medical service corresponding to the standard practice in properly equipped hospitals.

References

  1. Gholami, S.S. and T.F. Lue, Correction of penile curvature using the 16-dot plication technique: a review of 132 patients. J Urol, 2002. 167(5): p. 2066-9.
  2. Montague, D.K., Penile prosthesis corporotomy closure: a new technique. J Urol, 1993. 150(3): p. 924-5.
  3. Agatstein, E.H., J.H. Farrer, and S. Raz, Fracture of semirigid penile prosthesis: a rare complication. J Urol, 1986. 135(2): p. 376-7.
  4. Bozkurt, I.H., et al., Spontaneous bilateral rod fracture of malleable penile prosthesis. Can Urol Assoc J, 2014. 8(9-10): p. E739-40.
  5. Lee, W.H., et al., Spontaneous breakage of malleable penile prosthesis. Int J Impot Res, 1998. 10(4): p. 255-6.
  6. Lockyer, R. and C. Gingell, Spontaneous breakage of malleable prosthesis. Int J Impot Res, 1999. 11(4): p. 237.
  7. Pinheiro, M.A., et al., Multiple Site Fracture of Both Rods in a Malleable Penile Implant. Case Rep Urol, 2016. 2016: p. 9564904.
  8. Eid, J.F., Penile Implant: Review of a "No-Touch" Technique. Sex Med Rev, 2016. 4(3): p. 294-300.
  9. Levine, L.A., et al., Penile Prosthesis Surgery: Current Recommendations From the International Consultation on Sexual Medicine. J Sex Med, 2016. 13(4): p. 489-518.

Submit your own video!

We welcome you to participate in the Journal of Sexual Medicine (VJSM)